Equflow Flowmeter Solutions
for COVID-19 Vaccine Productions
Equflow’s flowmeters are being used in various processes supporting vaccine development to fight COVID-19. Examples of such processes in which flow control is essential, are:
- Chromatography
- Tangential flow filtration (TFF), cross flow filtration (membrane filtration)
- Filling and dosing operations
In order to avoid cross contamination Equflow’s single use concept of flowmeters is greatly appreciated in various applications.
Interested in more information?
Why Equflow?
- Over 20 years of experience
- Proven track record
- Engineering support
- Short lead times
Contact us
If you would like more information regarding our Flow Meter Solutions
or if you have a question about our products, please fill in the contact form down below.
Or contact us directly:
Phone number: +31 24 37 92 666
Email address info@equflow.com
Innovative Flowmeter Solutions
Indesign opportunities
- We design customized products to create a perfect fit in your vaccine production process
- Suitable for dosing and filling operations
- We offer engineering support during your process of testing and validation
- Fully adopted by the biopharmaceutical industry
- Excellent price/performance ratio
Medical (Devices)
Featured products

PVDF Clamp
Flowmeter
Key characteristics:
- Small size enables easy mounting onto device
- For easy and fast exchange of the wetted parts

PVDF Tubeholder
Flowmeter
Key characteristics:
- Measure up to 200 L/min
- Stable housing enables easy mounting onto device

Stainless Steel
Flowmeter
Key characteristics:
- High chemical resistance
- Sanitary Tri-Clamp
process connector available - Outstanding performance in higher process pressure

Barcode Scanner
Key characteristics:
- Automatic calibration system
- Data is saved in a two dimensinal barcode
- Can be used with any disposable flowmeter
Disposable Single Use Flowmeters
Advantages
- Can easily be designed into devices and systems
- Reduce down-times during your production process
- Avoids cross-contamination
- Designed for a fast and easy exchange of the wetted parts
- Calibration data per flow tube available
- Available in PVDF material (gamma radiation resistant) or PFA material (chemical resistant)
Technical
Specifications
- Flow ranges from 20 mL/min to 200 L/min
- Accuracy of measurements: 99%
- Repeatibility of measurements: 99.85%
- Suitable for low-viscous liquids
- Also suitable for opaque and corrosive
liquids - PVDF material can be exposed to gamma radiation up to 50 kGy
- High resolution square wave output